Model J240 Dual Pulse Generator Specifications
|
| FUNCTION |
|
Externally-triggered complementary-output pulse generator |
| INPUT |
|
- Rising-edge trigger, 50 ohm input impedance
Threshold is adjustable from -4 to +4 volts.
Threshold test point is provided.
|
| OUTPUT |
|
Complementary pulse outputs, adjustable from 0 to 800 millivolts peak into 50 ohm load
Nominal 5 ohm output impedance
J240-1 and -2 are capacitive coupled
J240-3 is DC coupled LVPECL.
|
|
PROPAGATION
DELAY |
|
800 ps nom |
| JITTER |
|
Below 1 ps RMS |
| SIZE |
|
3.3 x 2.1 x 0.9 inch extruded enclosure |
| POWER REQUIRED |
|
+12 volts, 150 mA max, 2.5x5.5 mm power connector.
Highland J12 power supply furnished.
|
| PACKAGING |
|
3.3 x 2.1 x 0.9 inch extruded aluminum enclosure. |
| OPERATING TEMPERATURE |
|
0 to 50degrees C, operating
0 to 95% humidity, non-condensing |
| INDICATORS |
|
Green power LED |
| VERSIONS |
|
J240-1 120 ps nominal Gaussian pulse outputs, rising-edge trigger
J240-2 Input follower, nominal 50 ps 20:80 rise/fall time
J240-3 LVPECL version of J240-2
|
| CONNECTORS |
|
- SMA standard; SMB and LEMO optional
|