home Highland company profile Highland Technology products Highland news applicationnotes email Highland Technology links
MODEL V450 VME
ANALOG INPUT MODULE

Also available: V470 Analog Output Module

Highland Technology logo
V450 analog input module features
  • 16 channels of fully isolated analog input acquisition, each independently programmable for mode and input range.

  • Voltage mode: input ranges from ±25 mV to ±250 volts.

  • Thermocouple mode: reports temperature for types
    J K E T R S B N.

  • Includes four non-isolated precision RTD signal conditioners, plus one on-board temperature sensor.

  • Reports thermocouple loop resistance and detects open thermocouples without inducing offset errors.

  • 24-bit basic ADC resolution.

  • No realtime handshaking required—once channel parameters are set up, measurements appear in dual-port memory registers with VMEbus-speed access.

  • Supports one or two optional 8-channel J470 isothermal junction boxes, each with integral RTD reference junction sensor, or one or two J475 field-wiring interface boards.

  • Test connector supports in-crate calibration check.

  • Optional built-in self test (BIST).

  • Clearly labeled dipswitches set VME address; no jumpers, headers, or trimpots.
The V450 is a VME 16-channel isolated analog-to-digital converter module which can acquire a wide range of DC voltages, including thermocouple temperatures. Each channel is independent with an isolated DC power supply, optoisolated interface, A/D converter, signal conditioning, input protection circuits, and test relay.

An internal microprocessor manages all data I/O and communicates with the VME bus via a transparent, VMEbus-speed dual-port memory.

Each channel may be user programmed to operate in voltage-input or thermocouple acquisition mode. In each mode, channel operating parameters, acquired measurements, and status flags are accessible in dedicated VME registers. Data rate/filtering options are provided. Data acquisition is managed autonomously by the processor, so VME masters may set channel parameters or read acquired measurements at any time at full VMEbus speed. Any channel can be associated with any of the reference junction sensors located in the external field-wiring termination panels, or can use the on-board sensor. Cold-junction compensation is via table lookup of thermocouple potential for the type currently selected. Reference junction temperatures are readable.

V450 VME Analog Input Module Specifications
FUNCTION 16-channel isolated voltage/thermocouple input.
COMPLIANCE IEEE 1014 VME; A16:A24:D16; no byte writes.
Thermocouple tables based on NIST/ITS-90.
RTD tables per IEC-751 for "385" curve RTDs.
PACKAGING 6U single-wide VME module
DEVICE TYPE 16-bit VME register-based slave: A24:A16:D16; implements 256 16-bit registers at switch-selectable addresses in the VME 16- or 24-bit addressing spaces.
CHANNEL INPUTS 16 channels, programmable functions, galvanically isolated
RANGES Programmable per channel.
Voltage: 14 bipolar ranges, ±25 mV, 50 mV, 80 mV, 125 mV, 250 mV, 500 mV, 1.25V, 2.5V, 5V, 12.5V, 25V, 50V, 125V,
250 V.
Thermocouples: types J K E T R S B N.
RESOLUTION Voltage mode, 24 bits.
Temperature mode, 0.0625 ºC.
OFFSET ERROR Ranges < 1 volt: ±1 uV over time/temperature.
Ranges >= 1 volt: ±20 PPM over time/temperature
GAIN ACCURACY Ranges < 1 volt: ±100 PPM of range ±15 PPM/ºC.
Ranges >=1 volt: ±250 PPM ±50 PPM/ºC.
SAMPLE RATE Programmable per channel, 4 to 500 readings/second.
NOISE REJECTION > 80dB rejection of 50/60 Hz noise at default sample rate of 16.7/second.
INPUT IMPEDANCE 1G min on ranges below 1 volt.
1M min on ranges above 1 volt.
PROTECTION ±350 volts differential.
±750 volts common-mode.
ESD to 15KV, human body model.
RTD INPUTS Four separate non-isolated external reference junction inputs,
4-wire platinum RTD sensor,
100 ohm or 1K, ISO "385" curve.
Resolution 0.0625 ºC.
Protected against shorts, ESD.
ONBOARD SENSOR Semiconductor reference junction temperature sensor,
±2 ºC typ accuracy.
OPERATING TEMP 0 to 60 ºC; extended MIL/COTS ranges available
CALIBRATION INTERVAL One year
CONNECTORS Two D-25 female, each 8 channels + 2 RTDs.
One D9 male, test/calibration check.
INDICATORS LEDs indicate VME access, CPU activity, error conditions. Additional LED flashes user programmable pattern.
POWER REQUIRED VME +5 volts, 1 amp max.
VME ± 12 volts, 10mA.
Also available: V470 Voltage/Thermocouple Output Module
home | products | contact us
Highland Technology - Copyright ©2005 All rights reserved
Phone: 415.551-1700  Fax: 415.551-5129